Built for business. Engineered to perform

Commercial Garage Doors for Every Industry

Open-Back 24- or 25-ga Steel Doors (OBI 2024HD, OB 2024HD, OBI 2025MD, OB 2025MD)

With or without polystyrene insulation. Engineered for dependable commercial performance.

Garaga residential garage door with the Deep Grooves design

— 10'x 10' doors, Deep Grooves design, Commercial White, Smooth steel

Heavy-Duty 24- or 25-ga Steel Doors (EPS 2024HD & EPS 2025HD)

Available with two steel exterior skin gauges. Ideal for more demanding industrial and high-traffic environments.

Garaga residential garage door with the Deep Grooves design

— 10'x 10' doors, Deep Grooves design, Commercial White, Smooth steel

Heavy-Duty 26-ga Steel Doors (EPS 2026HD)

Durable doors that add value to institutional, commercial, and industrial buildings with medium to high traffic.

Garaga EPS 2026HD commercial garage door in White, Light Grooves design, 23" x 13" windows and Uniform woodgrain steel.

— Light Grooves design, White, 23''x13'' windows, Uniform woodgrain steel

Medium-Duty 26-ga Steel Doors (EPS 3026MD, EPS 2026MD, EPS 1526MD)

Durable steel doors available in 3 insulation levels and thicknesses for lasting commercial performance

Garaga 16' x 14' commercial garage door in White with the Flush design, one window and Uniform woodgrain steel.

— 16'x14' door, Flush design, White, one window, Uniform woodgrain steel

Get your price now

Free Quote

All-Glass Doors (G-4000)

One of the industry's strongest full-view aluminum doors, built for lasting performance and demanding commercial applications.

Garaga G-4400 commercial garage doors, 13-1/2' x 14' all-glass, Anodized frame and Clear glass.

— 13-1/2'x14' all-glass doors, Anodized frame, Clear glass

Polyurethane-Insulated 26-ga Steel Doors (G-5000)

Our top performer in energy efficiency and strength. Available in 10 colors, 3 insulation levels, and 3 thicknesses to meet the needs of virtually any commercial or industrial building.

Garaga G-5000 commercial garage doors in Black, 14' x 14', Grooved design, Long windows and Uniform woodgrain steel.

— 14'x14' doors, Grooved design, Black, Long windows, Uniform woodgrain steel

Get your price now

Free Quote

FAQ

Are commercial and industrial overhead doors the same thing?

Commercial overhead doors are sectional doors built with panel construction, sized and reinforced for commercial and industrial buildings. Garaga's commercial range, including the G-4400, G-5000, EPS and OBI/OB series, is made up of sectional overhead doors rather than roll-up doors.

Which commercial garage door model is right for my building?

It depends on the use. The G-4400 is a full-view aluminum door for storefronts and showrooms, the G-5000 is a 3-layer insulated steel door for energy-conscious commercial or industrial buildings, EPS models suit medium to high-traffic industrial and institutional buildings, and OBI/OB open back doors are steel doors built for dependable commercial performance with or without insulation.

Should I choose a steel or aluminum commercial garage door?

Aluminum suits full-view applications: the G-4400 is a full-view aluminum door, non-insulated and 1-3/4'' thick, built for demanding commercial use. Steel suits insulated or heavy-duty applications: the G-5000, EPS and OBI/OB series are all steel doors, ranging from 1-1/2'' to 3'' thick depending on the model.

What R-value do commercial garage doors come in?

It varies by series. The G-5000 offers R-12, R-16 or R-18 depending on thickness, the EPS 2024-2025HD and EPS 2026HD offer R-8.7, the EPS 3026 series offers R-7, R-8.9 or R-15.1, and the OBI/OB series offers R-7.2 or no insulation. The G-4400 is non-insulated.

What is the difference between insulated and open back commercial doors?

Insulated doors use layered steel construction with foam insulation between the skins, as in the G-5000 and EPS series. Open back doors, like the OBI/OB series, are 1-layer non-insulated steel doors, or can be built as 2-layer doors with polystyrene insulation, so the same series covers both insulated and non-insulated options.

Are commercial garage doors sectional or roll-up?

Garaga's commercial doors are sectional overhead doors, built from panel sections such as the 3-layer steel construction of the G-5000 and EPS series or the full-view aluminum panels of the G-4400. There is no roll-up product in this range.

How is a commercial garage door different from a residential one?

Commercial doors are built heavier for more frequent use. Residential doors run 1-3/8'' to 2'' thick versus 1-3/8'' to 3'' for commercial, and use 2'' track hardware versus 2'' or 3'' thicker steel hardware commercially. Residential springs are rated around 10,000 cycles for about two openings a day, while commercial loading dock doors cycling 25 to 50 times a day use springs rated 25,000 to 100,000 cycles. Residential openers are 1/2 or 3/4 HP at 115 volts, commercial openers run 1/2 to 1 HP at 115, 220 or 575 volts.

What R-value garage door do I need?

R-value measures resistance to heat flow, so a higher number insulates better. Garaga recommends at least R-10 for an attached unheated garage, at least R-12 for an attached heated garage, a lightly insulated or non-insulated door for a detached unheated garage, and at least R-16 for a garage used as a workshop or gym. Thermal breaks and weatherstripping also matter, not just the R-value number.

What determines the cost of a commercial garage door?

Cost depends on the door itself, chosen window openings, hardware, opener and installation. Spring systems come standard at 10,000 cycles with options up to 100,000, and lift type, standard, high-lift or full vertical-lift, affects price. Openers vary by voltage, horsepower and mounting, and installation cost differs between new construction and replacement. Heavier use calls for stronger hardware.

How much headroom does a commercial garage door need?

It depends on lift type and hardware radius. With standard lift, a 2'' commercial door 8 to 12 ft high needs 12 in. of headroom with a 12 in. radius; over 12 ft it needs 13-1/2 in. with a 12 in. radius or 15 in. with a 15 in. radius, and a 3'' industrial door needs 15 in. Standard lift should not be used with more than 2 ft of headroom, use high lift instead. Low headroom hardware needs only 4 in. at the rear and 8 in. at the front for an 8 to 12 ft door, and a trolley operator adds 2-1/2 in.

Garaga dealer’s salesperson in a garage door showroom

Consider It Handled.

Your Garaga Pro Dealer makes the process easy, so you can enjoy the best part: loving the result.

Ready to Get Your Commercial Door Project Moving?